Lead length Dimensions(mm)
A B C D E
Regular L□F-C 11.5±0.7 38±3 3.3±0.2 3.6 or below 1.0±0.05
Long L□F 11.5±0.7 68±3 3.3±0.2 3.6 or below 1.0±0.05

Specification

Type No. Rated functioning temperature Tf(℃) Functioning temperature
(℃)
Holding temperature Th(℃) Maximum use temperature(℃) Maximum temperature limitTm(℃) Electrical rating
Ampere
(A)
Voltage
(V)
L3F 115 111±2 95 85 200 5.0 AC250
90 85 7.0 AC125
80 80 8.0 DC50
L4F 127 123±2 105 90 200 5.0 AC250
100 90 7.0 AC125

Safety standard information

Type No. Safety standard approval
PSE UL C-UL VDE CCC KC
L3F JET5823-32001-1003
(AC250V)
E73591 E73591 40016342 2008010205277035
(AC250V)
SU05028-10001
(AC250V)
L4F JET5823-32001-1004
(AC250V)
E73591 E73591 40016342 2008010205277035
(AC250V)
SU05028-10004
(AC250V)